Shenzhen Puxin Technology Co., Ltd.

Biogas flow meter

Biogas flow meter
Product Detailed

New design structure, advanced technology, convenient installation, accurate measurement.

JBD series of the gas meter are applicable to man-made and natural gas, LPG, air, and other no corrosive gases. The technical parameters of product satisfy the “GB/T6968 -97 gas meter” requirements. The product is the ideal choice of the gas meter.

Features:

New design structure, advanced technology, convenient installation, accurate measurement.

 

The shell of JBD1. 6 - SA. JBD2. 5: SA gas flow meter is made of aluminium alloy by casting. It has a good looking appearance,reasonable and compact inside structure. The design is excellent. The product is precise with small loss of pressure in measurement, and reliable.

 

Main Technical Parameters

Model

JBD2.5-SA

Accuracy

B level

Nominal flow rate Q

2.5 m3/h

Maximum flow rate Qmax

4 m3/h

Minimum flow rate Qmin

0.025 m3/h

Maximum working pressure

10 kpa

Basic difference limit

When Qmin≤Q≤0.1Qmin ≤±3%

When 0.1Qmax≤Q≤Qmax ≤±1.5%

Pressure loss

In Qmax, ≤200Pa

Air tightness

No leak under 10KPa

Long term performance

Fit the Durability Test B Level Standards GB/T696B-1997

Work Temperature

-10- +40 °C ≤85%RB

Gas meter joint thread

M30x2

Gas meter joint center distance

130mm

 

HS CODE: 90268000

 

 